sns share

K200S & K300S

Features

Features

K200S Features

  • - Small- and medium-scale control with 384 points
  • - High-speed processing (0.5㎲/step)
  • - On-line editing
  • - Change I/O value by force
  • - Small- and medium-sized manufacture line control by network
  • - Various special modules: analog, HSC, positioning, etc
  • - Built-in flash memory

K300S Features

  • - Small- and medium-scale control with 1,024 points
  • - High-speed processing: 0.2㎲/step
  • - On-line editing
  • - Change I/O value by force
  • - Small- and medium-sized manufacture line control by network
  • - Downsizing and high performance
  • - Various special modules: analog, HSC, PID, positioning, etc

Specification

Specification

Specifications
Item K3P-07AS K3P-07BS K3P-07CS
Operation method Cyclic execution of stored program, Time-driven operation, Interrupt task operation
I/O control method Scan synchronized batch processing method (Refresh method), Direct method by program
Program language Mnemonic, Ladder
Number of instructions Basic 30
Application 218
Processing speed 0.5㎲/Step
Program memory capacity 7Ksteps
Memory device P (I/O Relay) P0000~P31F (512 points) *1)
M (Auxiliary relay) M0000~M191F (3,072 points)
K (Keep relay) K0000~K031F (512 points)
L (Link relay) L0000~L063F (1,024 points)
F (Special relay) F000~F063F (1,024 points)
T (Timer) 100ms T000~T191 (192 points)
10ms T192~T255 (64 points)
C (Counter) C000~C255 (256 points)
S (Step controller) S00.00~S99.99 (100 x 100)
D (Data register) D0000~D4999 (5,000 words)
Timer type ON Delay, OFF Delay, Integration, Monostable, Retriggerable timer
Counter type Up, Down, Up-Down, Ring counter
Special function On-line editing, Change I/O value by force
Operation mode Run, Stop, Pause, Debug
Max. expansion stage Main base only *2)
Self-diagnosis functions Watchdog timer, Memory error, I/O error, Batter error, Power supply error
Built-in functions Cnet (RS-232C) PID control Cnet (RS-422/485)RTC function PID control Cnet (RS-232C)HSC (50kHz)RTC function
  • *1)With a 32-point I/O installation, P area is P0000~P023F and the rest of it is available to Use as internal memory.
  • *2)The suitable power module for GM6-B12M is GM6-PAFC, which can't support an analog Module. For analog modules or TC module, you are supposed to use GM6-PAFB or GM6-PDFB considering internal current consumption of each module. Communication modules are not to be installed in after slot number 7.
Specifications
Item K4P-15AS
Operation method Cyclic execution of stored program, Time-driven operation, Interrupt task execution
Programming language Ladder, Mnemonic
I/O control method Scan synchronized batch processing method (Refresh method), Direct method by program
Number of Instructions Basic 30
Application 218
Processing speed 0.2 ㎲/Step
Program memory capacity 15K steps
Data Type P (I/O relay) P0000~P31F (1,024 points)
M (Aux. relay) M0000~M191F (3,072 points)
K (Keep relay) K0000~K031F (512 points)
L (Link relay) L0000~L063F (1,024 points)
F (Special relay) F000~F063F (1,024points)
T (Timer) 100ms T000~T191 (192points)
10ms T192~T255 (64points)
C (Counter) C000~C255 (256points)
S (Step controller) S00.00~S99.99 (100 x 100 step)
D (Data register) D0000~D4999 (5,000 words)
Timer type ON Delay, OFF Delay, Integration, Monostable,
Retriggerable timer
Counter type Up, Down, Up-Down, Ring counter
Special functions RTC, On-line editing, Change I/O value

Download

検索
  • Software

    [PLC]KGLWIN_V3.63 for Master-K PLC (Japanese)

    2017.03.02 Japanese 6MB

    [PLC]KGLWIN_V3.63 for Master-K PLC (Japanese)

FAQ

自動化ソリュ-ション
グリーンビジネス電力ソリュ-ション自動化ソリュ-ション
PLC
Process AutomationLow Voltage VFDMedium Voltage VFDServo Drive & Motor (XGT Servo System)SoftstarterRemote I/OHMIPLC
MASTER-K Series
GLOFA-GM SeriesMASTER-K SeriesXGT SeriesXGB Series
K200S & K300S
K120SK200S & K300SKGLWIN

販売店をご確認ください。

ショートカット
  • Technical Question K200S & K300S

    [PLC] Master-K300 Cable Connection

    The cable connection diagram is as follows: PLC PC 2 ------- 3 3 ------- 2 5 ------- 5
  • Technical Question K200S & K300S

    [PLC] Controlling with RTC (Real Time Clock) of PLC (K200S)

    In case of K200S The memory addresses representing time-concerned information in K200S are looked at in four sections, F053 through F057, in 16 bits as follows: F053: Upper 2-digit numbers in Year, and Month F054: Date and Hour F055: Minute and Second F056: Lower 2-digit number in Year and Day. To utilize them separately, those memory addresses, F053 through F056, should be divided into an upper-8-bit memory and a lower-8-bit memory, each. For example, [BMOV F053 D0 H8008] [BMOV F054 D1 H0008] In that case, Year data will be moved into D0 address, as Month data into D1. The rest of time-concerned memory addresses are the same as above
  • Technical Question K200S & K300S

    [PLC] Effective date range

    It is as below to the range of the effective date of PLC. 1984 year Jan 1’st 1hour 0min 0sec ~ 2083 year Dec. 31’st 23hour 59min 19sec.
  • Technical Question K200S & K300S

    [PLC] RTC function (K200S)

    Yes, it is not built-in to the RTC function in K3P-07AS CPU module. And there is no RTC option module like K80/K120S. If you use RTC function, you have to use CPU module of K3P-07BS or K3P-07CS Type
  • Technical Question K200S & K300S

    [PLC] How to set up the communication between K300S G4L-CUEA and OPC Server

    Please refer to the attachment about it